Views: 214 Author: Saijia Acoustic Publish Time: 2026-11-25 Origin: Site
On October 28, 2026, the 400 m² variety studio system project at Qingyuan Radio and Television Station’s new facility—covering interior fit-out, lighting, audio, acoustics and stage machinery—passed a one-time contractual acceptance inspection. The acceptance report was marked “Accepted,” with a final conclusion of “Qualified.” All 8 acceptance categories and 13 acceptance items passed, with no outstanding issues. Based on the acceptance report and third-party test report SSD202600259 issued by the South China National Center of Metrology (Guangdong Institute of Metrology), this article documents the delivery results of the studio’s integrated audiovisual systems from the perspectives of acceptance and on-site measurement.
For a broadcast-grade studio, “completed” and “compliant” are two different things. The acceptance report addresses procedural and checklist requirements: whether equipment was delivered in the contracted brands and models, whether its technical performance met the specified requirements, and whether quality documents were complete. The test report addresses physical performance: the actual measured reverberation time, illuminance and color temperature—key parameters that directly affect audio and image quality. Together, the two documents provide a complete, verifiable and traceable record of project delivery.
Rather than following the conventional case-study sequence of “project background—system configuration—construction process,” this article begins with acceptance. Chapter 1 presents the acceptance conclusion and measured data; Chapters 2 and 3 explain the acceptance process and third-party testing criteria; Chapters 4–8 retain the project overview, system configuration, design-stage calculations, design highlights, construction challenges and on-site results. The FAQ and procurement pitfalls focus on acceptance criteria, measured verification and cross-border purchasing.
This article and the “Qingyuan Radio and Television Station 400 m² Variety Studio System Project” case study in the Projects section cover the same project from complementary perspectives. The case-study page documents the design and construction process, while this page focuses on acceptance and measured results; the two pages are intended to cross-link. Readers interested in the existing-site survey and construction organization can refer to the case study. Chapter 5 here works backward from measured values to the design-stage assumptions, while Chapters 1–3 provide the acceptance conclusions and measured performance criteria.
The conclusion first: the 400 m² variety studio system project at Qingyuan Radio and Television Station’s new facility passed a one-time contractual acceptance inspection on October 28, 2026. The report was marked “Accepted,” the final conclusion was “Qualified,” all 8 acceptance categories and 13 acceptance items passed, and the field for “Outstanding issues and recommendations for improvement” states “None.”
The measured results are also documented. Report SSD202600259, issued by the South China National Center of Metrology (Guangdong Institute of Metrology), records the following: for building acoustics, measurements at 7 unoccupied-room points using the interrupted-noise-source method under GB/T 50076-2013 produced averages of 0.64 s at 500 Hz and 0.68 s at 1,000 Hz, with an octave-band reverberation time of 0.66 s across 500–1,000 Hz. For stage lighting, average horizontal illuminance across five stage zones ranged from 3,041 to 3,133 lx, a spread of only 92 lx. Color temperature at 8 measurement points ranged from 5,667 to 5,717 K, a spread of 50 K—well within the ±150 K tolerance.
The article is organized as an acceptance record. Chapter 2 reconstructs the organization, basis and close-out process for the one-time contractual acceptance; Chapter 3 explains the third-party measurements and assessment criteria item by item. From Chapter 4 onward, the project overview, system configuration, design stage, design highlights, construction challenges and on-site results are retained for readers seeking further technical detail. The FAQ and procurement guide focus on acceptance criteria and measured verification for cross-border projects.
The 400 m² variety studio system project at Qingyuan Radio and Television Station completed its one-time contractual acceptance in October 2026. According to Chapter 9, “Acceptance Conclusion,” of the project acceptance report, the project passed acceptance and received a final rating of “Qualified,” with “None” recorded for outstanding issues and recommendations for improvement. Unlike descriptions limited to design specifications, this chapter uses the report’s project information, acceptance organization and method, acceptance scope and criteria, inspection notes, conclusion, and signature/seal pages to reconstruct the complete delivery process—from equipment supply and installation/commissioning to renovation of operational rooms, training and delivery confirmation. It also provides a reference for broadcasters and integrated media centers organizing acceptance for similar variety-studio projects.
The project used a one-time acceptance process organized by an appointed procurement agency/third-party organization; it was not accepted in separate stages or milestones. The purchaser, Qingyuan Radio and Television Station, appointed Guangdong Hexin Tendering Agency Co., Ltd. to organize the acceptance. Guangzhou Nanyue Engineering Construction Supervision Co., Ltd. served as the project supervisor, and Guangzhou Saijia Acoustic & Lighting Engineering Co., Ltd. was the successful bidder/contractor. The acceptance team comprised representatives of the purchaser, acceptance organizer, supervising party and supplier, together with personnel responsible for requirements, actual use and professional technical review.




The two tables show that acceptance was not limited to checking whether equipment had arrived. It also covered technical performance, installation and commissioning status, quality certificates, safety standards, contractual delivery time/location/method, and delivery-related elements such as technical-document handover, operator training and after-sales service commitments. The seven major systems were checked against the relevant acceptance items, including lighting and stage machinery, audio, large-screen display, intelligent centralized control, air conditioning and power distribution, motorized seating and furniture, acoustic fit-out, and renovation of auxiliary functional rooms.
Section 9.6, “Acceptance Notes and Existing Issues,” of the acceptance report states that all goods under the contract were checked item by item against the brands, models, specifications and quantities in the Contract Procurement List. All goods had arrived and been installed and commissioned; their appearance was intact; accompanying documents, including factory certificates and inspection reports, were complete and consistent with the contract; and delivery times and locations met the contractual terms. A comprehensive project inspection confirmed completion of all contracted equipment supply, installation and commissioning, renovation of operational rooms and training. System functions met the design requirements, renovation quality was acceptable and fit for use, and technical documentation was complete. The project was therefore ready for acceptance.
The “Outstanding issues and recommendations for improvement” field explicitly records that no outstanding issue affecting acceptance of the goods was found. The final page is marked “Accepted” and “Qualified,” with “None” entered for outstanding issues and recommendations. This means that no unresolved rectification items remained between site mobilization and delivery confirmation, completing the full cycle of design, construction, integrated commissioning and acceptance.
For the end user, passing one-time acceptance is only the starting point. The acceptance documents provide an essential baseline for future operation and maintenance: the Contract Procurement List identifies equipment brands, models and quantities; quality certificates and factory inspection documents support warranty claims and spare-parts traceability; technical-document handover and operator training support routine operation by duty personnel; and after-sales commitments define response times and responsibilities. For similar projects, archiving the acceptance categories, items and conclusions in a structured checklist also helps verify at the design stage whether specifications can be measured, inspected and delivered. For example, illuminance, color temperature and color-rendering index in Section 3.1, and reverberation time, NR-30 and RASTI in Section 3.2, should have their measurement methods defined in the contract and acceptance criteria in advance, then be verified item by item through third-party testing at handover (see Section 3, “Third-Party Testing and Measured Performance”).
Note that this chapter reports the procedures and conclusions stated in the acceptance report. The acceptance report does not include on-site readings for the acoustic and lighting parameters. The specific measured data should therefore be taken from test report SSD202600259 issued by the South China National Center of Metrology (Guangdong Institute of Metrology), as discussed in Section 3. The design values in the tender’s technical specifications and the “Customer Design Requirements” used during testing are based on different criteria; this article presents them separately and does not convert or infer between them.
In addition to the procedural conclusion of contractual acceptance, the project obtained an 8-page test report, No. SSD202600259, issued by the South China National Center of Metrology/Guangdong Institute of Metrology. The report presents on-site measurements of reverberation time, background noise, sound insulation (sound level difference), stage-area illuminance and color temperature in the 400 m² variety studio. Each result was assessed as “meeting the requirements,” and the conformity statement on the cover reads “Complies with the customer’s technical requirements.” This is key evidence distinguishing well-written design specifications from performance that can actually be measured on site. Design clauses come from the tender documents; measured values come from a statutory metrology body with CNAS accreditation. Although their criteria differ, they corroborate one another and jointly support the delivery-quality record.

The test report was issued by the South China National Center of Metrology (Guangdong Institute of Metrology), a national statutory metrology verification body established by the State Administration for Market Regulation in South China. Its quality management system complies with ISO/IEC 17025:2017, and the report bears the CNAS L0730 accreditation mark. The report identifies the customer as Qingyuan Radio and Television Station and the sample as the “400 m² Variety Studio System Project procured by Qingyuan Radio and Television Station (interior fit-out, lighting, audio, acoustics and stage machinery).” The model/specification is 400 m²; the manufacturer is Guangzhou Saijia Acoustic & Lighting Engineering Co., Ltd.; sample management No. 20260818001#; and original record No. 2202600259. The sample was received and testing completed on September 15, 2026; the report was issued on September 18, 2026. The testing location is recorded as the third floor of Qingyuan City Museum, Qingyuan Avenue, Qingcheng District, Qingyuan. This is another location description for the same project site identified as “Qingyuan Radio and Television Station (New Facility)” in the acceptance report.
The testing standards were GB/T 50076-2013, Code for Measurement of Reverberation Time in Rooms; GB/T 50034-2024, Standard for Lighting Design of Buildings; and GB/T 19885-2005, Acoustics—Measurement of Sound Insulation Performance of Enclosures—Laboratory and Field Measurements. The assessment rule followed Clause 6.2.1 of CNAS-GL015:2022, Guidelines for Decision Rules and Statements of Conformity. Major instruments included a Type 2270 building-acoustics measurement system (10 Hz–20 kHz; sound-pressure-level measurement uncertainty U=(0.4–1.0) dB, k=2; reverberation-time relative uncertainty U_rel=1%), Type 4231 sound calibrator, Type 4292-L omnidirectional sound source (50–10,000 Hz), Type 2734 audio power amplifier, and CL-200A/CL-200M color illuminance meters for illuminance and color-temperature measurements. Instrument IDs, certificate numbers and traceability information were listed. The specified test conditions were 29°C and 58% relative humidity.
The first part of the report covers sound pressure level difference (sound insulation performance) testing. Measurement points were selected according to the client’s requirements (see the schematic in Figure 2). During testing, all interior doors and windows were closed, the air conditioning was turned off, and surrounding areas were operating under normal conditions, with care taken to ensure no anomalous noise interference. The second part, background noise testing, was conducted under the following conditions: "surrounding areas of the variety show studio operating normally with no anomalous interference; equipment and air conditioning turned off." A summary is provided below:


Reverberation time was measured using the interrupted sound source method, as requested by the client, with an architectural acoustics measurement system (equipped with recording capabilities) used to directly determine the room's reverberation time (T). Measurement points P1–P7 were distributed throughout the variety show studio (including locations on the stage and in the audience area), with microphones positioned at a height of 1.4 m and the sound source located at S1; the space was unoccupied (empty). The readings for the 500 Hz and 1000 Hz frequency bands are as follows:

The average values for these two frequency bands are 0.64 s and 0.68 s, respectively. The report indicates a reverberation time of 0.66 s for the 500 Hz–1000 Hz octave band, which falls within the client’s design requirement of 0.65 ± 0.1 s. An analysis of the dispersion across the seven measurement points—ranging from 0.61–0.66 s at 500 Hz and 0.66–0.70 s at 1000 Hz—shows no instances of "localized tailing" (significant deviations at individual points) in either the stage or audience areas. The background noise level (NR-22) meets the criteria (better than NR-25), and the sound pressure level differences for the sound-insulating doors, windows, and walls all exceed their respective design values of 40 dB(A) and 50 dB(A). It should be noted that these values correspond specifically to the conditions outlined in the report—namely, an empty space with doors, windows, and air conditioning closed—and cannot be directly applied to scenarios where the venue is fully occupied or the air conditioning is in operation.
Section IV of the report, "Test Results for Illuminance and Color Temperature," provides two sets of readings for the stage area. Regarding illuminance (Table 4, titled "Summary of Horizontal Illuminance Measurement Results for the Variety Show Studio Stage Area"), measurements were taken at locations specified by the client, at a height of 1.5 meters. The client’s design requirement is stated as: "With the camera aperture set to f/5.6, the vertical illuminance of the combined lighting in the performance area shall be no less than 2000 lx." The conclusion is "Meets requirements."

Readings across five zones range from 3041 to 3133 lx, with a narrow spread (range) of only 92 lx, indicating a high degree of lighting uniformity between the center of the stage and the areas to the left and right. Regarding color temperature (Table 5), eight measurement points were established across the stage area. The client’s design requirement is 5600 ± 150 K; the average measured color temperature is 5697 K, and the conclusion is "Meets requirements."

The readings at the eight points fall between 5667 and 5717 K, with a range of 50 K—well within the ±150 K tolerance—providing empirical evidence for color consistency in multi-camera productions. The report does not provide on-site readings for metrics such as the Color Rendering Index (Ra), RASTI (speech intelligibility), or sound field non-uniformity; therefore, no numerical inferences are made here regarding these parameters. It should also be noted that while Table 4 is titled "Horizontal Illuminance," the client’s design requirement refers to "Vertical Illuminance." These terms are cited exactly as they appear in the original report; no conversions or calculations have been performed to derive vertical illuminance values from the provided data.
When comparing the test report with Section 6, “Design Highlights and Technical Innovations,” three distinctions in measurement criteria should be kept in mind:
Different sources of criteria: the tender’s technical specifications define design targets—reverberation time 0.70±0.1 s, NR-30, RASTI >0.65, vertical illuminance of at least 1,200 LUX at camera aperture 5.6, color temperature 5,600±150 K, and color-rendering index ≥95. The “Customer Design Requirements” column in the test report gives the acceptance criteria used for this test—reverberation time 0.65±0.1 s, NR-25, vertical illuminance ≥2,000 lx, color temperature 5,600±150 K, and acoustic door/window/wall sound level differences of 40/50/50 dB(A). The two sets of values come from different sources and apply to different conditions and purposes. They are therefore presented separately, without conversion or using one set to determine whether the other is compliant or non-compliant.
Specific test conditions: the report states that the customer supplied the test-site layout. Reverberation time was measured in an unoccupied room using the interrupted-noise-source method, with the microphone at 1.4 m. Illuminance points were measured at 1.5 m. Background-noise and sound-insulation tests were conducted with all doors and windows closed, air conditioning and equipment switched off, surrounding operations normal and no abnormal interference. Ambient conditions were 29°C and 58% relative humidity.
Defined assessment rule: the conformity statement was made in accordance with Clause 6.2.1 of CNAS-GL015:2022. The report also notes that the standards used for this test had not yet been included in the “one-list, one-database” management system; after consultation with the customer, the parties agreed to conduct testing under those standards.
Although the criteria differ, the two documents are independent and mutually supportive. The acceptance report provides the procedural conclusion—accepted, qualified, with no outstanding issues—while the test report provides the performance conclusion—compliant with the customer’s technical requirements. For broadcasters and integrated media centers, this combined evidence of “procedural acceptance + measured performance” is more useful for future retesting, comparison and allocation of responsibility than an acceptance checklist alone.
A key lesson from this project is to define specifications in terms that can be measured and retested. At the proposal and contract stages, specify frequency bands (500 Hz/1,000 Hz), the number and location of measurement points (P1–P7 and 8 color-temperature points), test conditions (unoccupied room, door/window and air-conditioning status), assessment rules and instrument traceability. At completion, appoint a CNAS-accredited third-party organization to perform on-site measurements and create a complete evidence chain containing the report number, original-record number, instrument certificate numbers, measurement-point layout and site photographs. Archiving the layout together with individual readings allows future retesting under the same conditions if lamp depreciation, aging absorptive structures or increased air-conditioning noise occurs. This makes it possible to identify whether a problem results from design, construction or changed operating conditions, rather than relying on subjective comments such as “the sound feels muffled” or “the picture looks slightly discolored.”
Project Overview
Project Element | Details |
Project name | Qingyuan Radio and Television Station 400 m² Variety Studio System Project (interior fit-out, lighting, audio, acoustics and stage machinery) |
Purchaser / end user | Qingyuan Radio and Television Station |
Procurement agency | Qingyuan Youce Project Management Co., Ltd. |
Budget | RMB 12,239,300.86 (approximately RMB 12.2393 million) |
Project location | Renovation and optimization of an existing space at Qingyuan Radio and Television Station (New Facility), Qingyuan, Guangdong Province, China |
Project scale | Studio floor area: approximately 400 m²; width: approximately 20 m; length: approximately 24.5 m; floor height: approximately 11 m; stage depth: approximately 11 m. Control room and equipment room: approximately 70 m². Auxiliary rooms include performer waiting area, VIP room, male/female dressing rooms and corridors. Total floor area: approximately 900 m². |
Intended use | Production of interviews, public affairs programs, quiz competitions, variety shows, press conferences and other formats; supports program recording for the Qingyuan Smart City 5G Integrated Smart Media Project. |
Seven major systems | 1) Lighting and stage machinery; 2) Audio; 3) Large-screen display; 4) Centralized control; 5) Air conditioning and power distribution; 6) Motorized seating and auxiliary-room support; 7) Acoustics. |
Design references | Applicable national and industry standards, including GY 5070-2013, GB/T 28049-2011, GY/T 5086-2012 and GY 5045-2006. |
Procurement project No. | GDYC25-ZC006 |
Successful bidder / contractor | Guangzhou Saijia Acoustic & Lighting Engineering Co., Ltd. (project contractor and system integrator) |
Contract amount | RMB 12,055,823.00 (different basis from the procurement budget of RMB 12,239,300.86) |
Supply and acceptance timeline | Contractual delivery: within 110 calendar days after contract signing and receipt of written notice. Actual deliveries were made in batches from June to September 2026; acceptance took place on October 28, 2026. |
Acceptance conclusion and organization | One-time contractual acceptance; accepted and finally rated qualified, with all 13 acceptance items passing. Acceptance organized by Guangdong Hexin Tendering Agency Co., Ltd.; supervision by Guangzhou Nanyue Engineering Construction Supervision Co., Ltd. |
Third-party testing organization | South China National Center of Metrology / Guangdong Institute of Metrology (CNAS L0730; quality management system compliant with ISO/IEC 17025:2017) |
Test report and measured results | Report No. SSD202600259; testing completed September 15, 2026 and report issued September 18, 2026. Reverberation time 0.66 s; background noise NR-22; acoustic door/window/wall 48.0/51.1/50.2 dB(A); illuminance 3,041–3,133 lx; average color temperature 5,697 K. Each item was assessed as “meeting the requirements”; conformity statement: “Complies with the customer’s technical requirements.” |
Centered on the variety studio, the project covers the stage, audience area, acoustic-treatment areas, control room and production/director’s room. It forms an integrated audiovisual system combining acoustics, lighting, video, stage machinery, control and power distribution. Each subsystem has its own function, while signal networks and a centralized control platform coordinate them to support rapid scene changes for different program formats.
Stage lighting serves three purposes: performance illumination, atmosphere creation and shaping images for television production. The machinery system supports lighting suspension, curtain operation and scene changes. Centered on a computerized lighting console (the project’s core product), the system uses multiple lighting bars and trusses and includes professional LED PAR lights, wash lights, moving-beam lights and profile/spotlights. Fixtures are arranged according to front light, side/front fill, top light, backlight, side light and followspot positions.
Light sources: priority is given to energy-efficient, environmentally friendly LED sources offering high luminous efficacy, low heat output and long service life.
Lighting approach: front light provides facial illumination; top light creates depth; backlight outlines subjects; wash and beam fixtures create atmosphere.
Control protocol: the standard DMX512-A protocol (WH/T 32-2008) is used, supporting network expansion and visual programming.
Stage machinery: lighting battens, electric hoists, grid and catwalks, main/valance/side/scrim curtains and related mechanisms, equipped with limit switches, brakes and emergency stops.
The audio system is designed for multipurpose use in accordance with GB/T 28049-2011, Code for the Design of Sound Reinforcement Systems in Halls and Sports Venues. A layout combining line-array main reinforcement, zoned fill speakers, stage monitoring and low-frequency reinforcement provides even sound coverage and clear speech intelligibility. Key issues addressed include uneven sound fields in large spaces, insufficient stage monitoring and microphone feedback, meeting the listening requirements of variety shows, interviews and press conferences.
LED displays form the visual center of the variety studio. The project includes a horizontal fascia screen at the stage opening for the station logo, subtitles and program titles; a main stage screen for backgrounds, video playback and scenic design; and supporting side/floor screens. Together, they create a layered visual environment. The displays must meet broadcast-grade color, high refresh-rate and wide-viewing-angle requirements, avoiding camera scan lines, moiré patterns and ripple artifacts. They are integrated with lighting, machinery and audio to create a unified stage presentation.
The centralized control system coordinates lighting scenes, video sources, audio routing, camera positions and curtain movements, reducing complex equipment operation and improving production efficiency. It comprises three layers: centralized control, program automation and a station-wide architecture monitoring platform. A unified technical platform with open interfaces, centralized resource management and resource sharing enables interconnection and overall management of the studio systems.
Power supply levels are determined according to the importance of operating loads. The system includes distribution cabinets, power cables, cable trays and outlets, grounding and lightning protection, UPS, lighting panels and fixtures, emergency lighting, electrostatic protection, leakage protection and grounding. A dedicated mains distribution cabinet is provided for computer equipment. Equipment rooms use compliant copper-core, low-smoke, halogen-free cables. Power and signal cables are routed separately in galvanized metal trunking/conduits and reliably grounded. Each air-conditioning unit has an independent power supply. Emergency switches allow rapid power isolation in the event of fire or other serious incidents.
The audience area is equipped with motorized seats, allowing the seating layout to be adjusted to different program formats, including variety shows, interviews, public affairs programs, quiz competitions and press conferences. Auxiliary spaces include performer waiting areas, a VIP room, male and female dressing rooms and corridors. Their fit-out, acoustic treatment and supporting facilities were completed alongside the main studio, creating a complete circulation route for production and reception.
Building acoustics underpin the studio’s audio and image quality. The design principle is to control background noise first and then optimize sound quality. Sound insulation, absorption and diffusion are used to control noise and reverberation and maintain speech intelligibility. Finishes include wall-mounted aluminum-faced absorptive elements, 150 mm-high stainless-steel skirting, professional PVC/self-leveling floor finishes, Class B fire-rated acoustic doors (sound insulation >40 dB), and ceiling absorbers made from expanded-metal mesh and aluminum panels. The design balances safety, practicality and visual quality.
At delivery, the seven major systems were not accepted through a general visual inspection alone. The acceptance report records system-by-system checks covering lighting and stage machinery, audio, large-screen display, intelligent centralized control, air conditioning and power distribution, motorized seating and furniture, acoustic fit-out, and auxiliary-room renovation. Together with equipment delivery, installation and commissioning, technical-document handover, operator training and after-sales commitments, all 13 acceptance items were judged qualified. See Section 2 for the relationship between systems and acceptance items, and Section 3 for measured acoustic and lighting data.
This chapter reviews the design-stage calculations. Geometric and construction parameters use design-stage values, and assumptions are identified in the text. All figures are design targets or calculated design values; they are not the same as the third-party measurements in Chapter 3 and are not converted or used to determine compliance against one another. Published acceptance and test data remain unchanged. The purpose of this review is to explain how the five groups of readings on the acceptance record were calculated at the design stage.
Test report SSD202600259 gives five groups of readings: an octave-band reverberation time of 0.66 s at 500–1,000 Hz; background noise NR-22; acoustic door/window/wall sound level differences of 48.0/51.1/50.2 dB(A); horizontal illuminance of 3,041–3,133 lx across five stage zones; and color temperatures of 5,667–5,717 K at eight points. These values did not arise on the acceptance date without prior planning. Each is linked to a design-stage criterion, standard and calculation model.
The relationships are as follows. Reverberation time corresponds to the tender design value of 0.70±0.1 s and the test criterion of 0.65±0.1 s, using the statistical-acoustics Sabine equation. Background noise corresponds to tender NR-30 and test criterion NR-25, using noise-rating curves and sound transmission through the building envelope. Sound insulation corresponds to the 40/50/50 dB(A) design thresholds, using component sound-reduction ratings and area-weighted composite construction calculations. Illuminance and color temperature correspond to vertical illuminance at camera aperture 5.6 and 5,600±150 K, using the utilization-factor method and color-tolerance control.
Table 1 | Relationship Between the Five Measured Results and Design Criteria
Measured parameter | Measured result | Test criterion | Tender design value | Design-stage calculation method |
Reverberation time (500–1,000 Hz) | 0.66 s | 0.65±0.1 s | 0.70±0.1 s | Sabine statistical reverberation + octave-band absorption balancing |
Background noise | NR-22 | NR-25 | NR-30 | NR rating curves + envelope/door/window sound transmission + silencer stages |
Acoustic door/window/wall | 48.0/51.1/50.2 dB(A) | 40/50/50 dB(A) | 40/50/50 dB(A) | Inversion of component Rw + area-weighted composite construction |
Stage horizontal illuminance (5 zones) | 3,041–3,133 lx | ≥2,000 lx (vertical illuminance) | ≥1,200 lx (vertical illuminance) | Utilization-factor method E=Φ·U·M/A |
Color temperature (8 points) | 5,667–5,717 K; average 5,697 K | 5,600±150 K | 5,600±150 K | Fixture-setting consistency + SDCM color tolerance + dimming curve |
The three columns use different criteria: tender design values come from the tender’s technical specifications, test criteria come from the “Customer Design Requirements” column of the report, and measured values come from on-site readings. They are listed separately and are not converted.
One more point: for parameters not measured in the report—color-rendering index Ra, RASTI, sound-field non-uniformity and floor impact sound—this chapter provides design calculations only and explicitly marks them as “not measured; no inference made.”
The first step in reverberation design is not material selection but determining the room volume. The studio’s building grid is 24.5 m × 20.0 m, with an 11.0 m floor-to-ceiling height, giving an envelope volume of 5,390 m³. Acoustic calculations cannot use the full envelope volume: the approximately 1.5 m-high grid, catwalk and pulley-beam layer above the suspended ceiling does not participate in sound propagation. The stage trap and side-stage volumes, side-light room, front-light bridge, and control/equipment rooms (approximately 70 m²) must also be deducted. Based on a 400 m² usable area and an equivalent clear height of 10.5 m, the net acoustic volume is V≈4,200 m³, with a range of 4,000–4,400 m³.
Once the volume is established, the calculation can be reversed. Using T60=0.161V/A, a target of 0.70 s requires total absorption A=0.161×4,200/0.70≈966 m² sabin. The measured 0.66 s corresponds to A=0.161×4,200/0.66≈1,025 m² sabin. The difference is 6%, which is the key relationship in this section: the design retained a margin, while the actual absorption provided by construction and furnishings was slightly higher than the design assumption.
Why retain a margin? Near the target, reverberation time is not highly sensitive to a small change in absorption. Increasing 966 m² sabin by 6% reduces reverberation time only from 0.70 s to 0.66 s; reducing absorption by 6%, by contrast, would raise it to 0.75 s, close to the upper acceptance limit. Setting the design balance point at 0.70 s rather than forcing it down to 0.66 s leaves room for later changes to soft furnishings, curtains and seating. The measured result indicates that this margin was neither wasted nor exhausted.
The Sabine equation was selected for another reason. At 500 Hz, the same model gives a Sabine value of 0.699 s and an Eyring value of 0.513 s—a difference of 27%. The measured 0.66 s is clearly closer to the Sabine result. Absorption in this studio is distributed by zone—ceiling, walls, wall bases and seating are treated separately—rather than being uniform across all surfaces as assumed by the Eyring model. The Sabine equation therefore better represents the actual arrangement. The calculation uses Sabine as the primary value and lists Eyring as a conservative lower bound; both are disclosed.
Passing at one frequency is not enough; each octave band must be considered. Of the 1,978.95 m² net surface area, the absorptive surfaces are allocated as follows: 343 m² of expanded-metal absorptive ceiling and 147 m² of closed aluminum ceiling; 638 m² of aluminum-faced wall absorbers, 201 m² of hard aluminum/wood finishes and 140 m² of membrane-type low-frequency wall-base absorbers; 210 m² of audience seating, 60 m² of aisles and 220 m² of stage timber flooring; and 19.95 m² of observation windows and acoustic doors. At 500 Hz, the calculated absorption totals 967 m² sabin, just 0.1% above the 966 m² sabin target.
Low frequencies are the most difficult. The 63 Hz band relies on membrane-type low-frequency construction: the 140 m² wall-base treatment uses an absorption coefficient of 0.90 at 63 Hz and 0.55 at 125 Hz, reducing the 63 Hz reverberation time to 1.161 s. Without this treatment, it would remain above 1.4 s. At higher frequencies, excessive absorption must be avoided. The ceiling and wall absorbers use coefficients of only 0.72 and 0.63 at 4,000 Hz, retaining some high-frequency reverberation so the studio does not sound acoustically “dead.”
Unoccupied and occupied conditions are two different operating cases. The unoccupied case matches the test condition: doors and windows closed, air conditioning off and seats empty. The calculated reverberation time at 500 Hz is 0.699 s. For the occupied case, 180 people are added at 0.45 m² sabin per person, giving 0.645 s at 500 Hz—0.054 s (7.7%) shorter than the unoccupied case. A shorter reverberation time with a full audience is expected; occupied values must not be compared directly with unoccupied measurements, or vice versa.
Table 2 | Octave-Band Design Calculations and Measured-Value Inversion (Unoccupied Room)
Octave band (Hz) | Design T60 (s) | Total absorption (m² sabin) | Average surface absorption coefficient | Measured T60 (s) | Inverted A (m² sabin) |
63 | 1.161 | 582.2 | 0.294 | Not measured | — |
125 | 0.824 | 820.2 | 0.413 | Not measured | — |
250 | 0.748 | 903.8 | 0.454 | Not measured | — |
500 | 0.699 | 967.1 | 0.484 | 0.64 | 1,057 |
1,000 | 0.697 | 970.1 | 0.481 | 0.68 | 994 |
2,000 | 0.721 | 937.8 | 0.452 | Not measured | — |
4,000 | 0.702 | 963.9 | 0.416 | Not measured | — |
8,000 | 0.542 | 1,248.2 | 0.376 | Not measured | — |
Note: This table represents the unoccupied condition. Total absorption = surface absorption + air absorption and excludes the audience (for the occupied condition, 180 people at 0.45 m² sabin per person are added; see the text). The average surface absorption coefficient = surface absorption ÷ net surface area of 1,978.95 m², and therefore is not equal to total absorption divided by surface area. The report provides measurements only at 500 Hz and 1,000 Hz; other bands are design calculations and are not inferred measurements. The measured 0.66 s octave-band reverberation time across 500–1,000 Hz corresponds to A≈1,025 m² sabin, 6% above the design value of 967 m² sabin.

Figure D-01 | Three-Way Comparison of Reverberation-Time Frequency Response: Design Calculations (Sabine/Eyring), Tender Target Band and Third-Party Measurements

Figure D-02 | Acoustic Fit-Out Zoning Plan: Absorptive and Diffusive Surfaces, Sound-Insulating Walls, Doors/Windows and Floating-Floor Areas
A more detailed inversion gives 1,057 m² sabin from the 0.64 s reading at 500 Hz and 994 m² sabin from the 0.68 s reading at 1,000 Hz. Compared with design values of 967/970 m² sabin, the absorption correction factors k are 1.09 and 1.02, respectively. The two-band residual RMSE is 0.043 s, with a mean deviation of +0.038 s. Both k values are greater than 1, consistently indicating that actual absorption exceeded the design assumptions. The increase is attributable to curtains, carpets, scenic elements and seat upholstery, at approximately 6%. The inversion tool requires at least three octave bands to solve k automatically. Since this report contains only two frequencies, k and RMSE are calculated directly across those two bands using the same definitions; no inference is made below 125 Hz or above 2,000 Hz.
The tender commitment was NR-30, the test criterion was NR-25, and the measured result was NR-22. Viewed side by side, these figures might be misread as “conservative design, but test failure.” In fact, they represent three successive levels with different roles: NR-30 was the value committed to the client at the design stage; NR-25 was the acceptance criterion adopted by the third-party test (5 dB stricter than the commitment); and NR-22 was the site reading (3 dB better than the criterion and 8 dB better than the commitment).
NR-22 was not achieved simply by adding silencers after construction. It resulted from five design decisions along the noise-control chain. First, air-conditioning units were located outside the main structure and installed on vibration-isolated bases. Second, the free-air velocity at supply outlets was limited to 1.5 m/s (1.2–1.5 m/s for studios). Regenerated outlet noise varies with the sixth power of air velocity; this measure is simple but often overlooked. Third, at least two stages of attenuation were provided in both supply and return ducts, using reactive/absorptive composite silencers and micro-perforated panels. Fourth, envelope elements, doors and windows were assigned conservative sound-insulation values and connected through an acoustic vestibule. Conservative lower-bound assumptions were deliberately used: a 240 mm plastered brick wall at Rw 50, insulated glazing at Rw 35, and a steel door at Rw 32, rather than the actual design values of 59/46/41 dB in Section 5.5. It is preferable to underestimate envelope performance and let silencers and vibration isolation provide additional protection, rather than overestimate the envelope and consume the margin in advance. Fifth, a 240 mm multi-damping sound-insulating wall separates the equipment room from the studio, with equipment-room noise controlled below 85 dB(A).
Using these assumptions, the room-acoustics model calculates an indoor background-noise rating of NR-21 from sound transmission through the external walls, doors and windows. The calculated NR-21, test criterion NR-25 and measured NR-22 differ by no more than 4 dB, indicating reasonable agreement between the envelope/door/window/attenuation model and site conditions. The air-conditioning and duct path—including unit noise, regenerated outlet noise and silencer stages—was separately designed to meet NR-30 and was to be verified by measurement during commissioning. This calculation does not infer numerical performance for that path.

Figure D-03 | Background-Noise NR Rating Curve and Margin to Limits: Tender Commitment NR-30, Test Criterion NR-25 and Measured NR-22
One operating condition must be clarified. The report states that background-noise testing was conducted with equipment and air conditioning switched off, while surrounding areas operated normally without abnormal interference. NR-22 therefore represents the background noise in the “off” condition. Background noise will rise when the air conditioning is running, so this value cannot be applied directly to that condition. The NR-30 design commitment and NR-25 test criterion were set with awareness of the off-state measurement; the 5 dB margin allows for operating conditions and changes in use.
The three sound-insulation figures are easy to misinterpret. The report gives on-site sound level differences, while the tender design thresholds are 40/50/50 dB(A). At the design stage, however, the controllable parameters are the sound-reduction rating Rw of each individual element and the apparent rating Rw,app of the combined construction. The acoustic model was used to invert the construction of the three elements, with layer order stated from the source side to the receiving side.
Acoustic door: 1.5 mm steel plate + 60 mm rock wool (100 kg/m³) + 1.5 mm steel plate. The surface density is approximately 62 kg/m², the element rating Rw is 41 dB and the apparent composite value is 42 dB—only 2 dB above the 40 dB threshold. The on-site result was 48.0 dB(A), 8 dB above the threshold. The improvement comes not from the door leaf but from the junction details: an acoustic vestibule, offset double doors, three magnetic sealing strips around the perimeter and a drop-down threshold seal. Door gaps and thresholds are traditional weak points; simply increasing steel-plate thickness cannot compensate for them.
Acoustic window: an inversion based on the closest available construction—8 mm glass + 100 mm air cavity + 8 mm laminated glass in independent double frames—gave an apparent value of only 47 dB, 3 dB below the 50 dB threshold. This shortfall was identified during design. The solution was to make the inner pane laminated, use panes of unequal thickness, tilt the inner pane approximately 5° toward the sound source and add elastic sealing strips. The measured result of 51.1 dB(A) met the requirement, showing that “double glazing” alone is insufficient; the laminated layer and pane angle account for the additional 3 dB.
Acoustic wall: the 200 mm reinforced-concrete wall itself has Rw 59 dB. However, after two doors and an observation window were installed, area weighting reduced the apparent value to 52 dB. The controlling element is the door, which contributes 60.7% of sound transmission. The measured 50.2 dB(A) is 1.8 dB below the apparent value of 52 dB, within a reasonable range for flanking transmission and construction gaps. This illustrates a counterintuitive point: making the wall thicker would not significantly improve the overall sound insulation.
Table 3 | Inverted and Measured Values for Three Sound-Insulating Elements
Element | Construction (source side → receiving side) | Element Rw (dB) | Composite apparent Rw,app (dB) | Field R'w (dB) | Measured sound level difference | Design threshold |
Acoustic door | 1.5 mm steel + 60 mm rock wool (100 kg/m³) + 1.5 mm steel; 3 magnetic seals + drop-down threshold seal; offset acoustic vestibule | 41 | 42 | 39.0 | 48.0 dB(A) | 40 dB(A) |
Acoustic window | 8 mm glass + 100 mm cavity (inner pane tilted 5°) + 8+8 mm laminated glass; independent double frames, unequal pane thickness | 46 | 47 | 44.0 | 51.1 dB(A) | 50 dB(A) |
Acoustic wall | 20 mm plaster + 200 mm reinforced concrete + 20 mm plaster (also 240 mm brick + 50 mm cavity with infill + double-layer gypsum sections) | 59 | 52 | 49.0 | 50.2 dB(A) | 50 dB(A) |
Rw is a single-number laboratory rating, while R'w is a field rating. The measured sound level difference uses a different basis from Rw; the values are therefore listed separately and are not converted.

Figure D-04 | Layer Sequence, Rw Frequency Characteristics and Apparent Values of Combined Sound-Insulating Elements
The combined-element calculation uses area-weighted transmission coefficients: 198.4 m² of wall (Rw 59), 9.6 m² of acoustic door (Rw 41) and 12.0 m² of observation window (Rw 46). The area-weighted apparent value is 52 dB, 7 dB below the wall itself. This directly explains why a design threshold of 50 dB(A) and a measured result of 50.2 dB(A) are reasonable: the door limits the wall assembly’s overall sound-insulation ceiling, and sound energy leaks through the smaller-area elements. To improve the entire wall assembly, the door must be upgraded and an acoustic vestibule added; thickening the wall will not solve the problem.
Impact sound is a separate issue and can be more difficult than airborne sound in a studio because motorized seats, stage machinery and lighting battens can all transmit structure-borne vibration. The calculated Ln,w value for a bare 120 mm cast-in-place concrete slab is 77.9 dB. With a 30 mm resilient rock-wool layer (density 100) and a 50 mm fine-aggregate concrete floating screed, the floating-floor resonance frequency is f0=50.3 Hz, the improvement is ΔLw=29.9 dB, and the design Ln,w is 48.0 dB.
A floating floor is not an isolated measure. It must be coordinated with resilient hangers, mineral-wool filling around pipe sleeves through walls and a floating floor in the equipment room to help maintain NR-22. The report did not measure floor impact sound, so Ln,w 48.0 dB remains a design calculation and must not be cited as a measured result. This distinction is identified separately in the comparison below.
The illuminance calculation starts from the camera requirements. The test criterion is “vertical illuminance of the combined studio lighting of at least 2,000 lx at camera aperture 5.6,” while the tender design value is 1,200 lx. Both values appear in the contract and test report but use different criteria, so they remain separately identified. The design-stage question is how many fixtures and how much luminous flux are required on stage to meet the criterion.
Lighting is divided into six groups: front light for facial illumination, side/front fill for lateral illumination, top light for depth, backlight for outlining, side light for contour and followspots for the main subject. The mechanical layout uses 7 lighting bars and 87 fixtures: 12 × 300 W LED profile fixtures for front light, 10 auxiliary front lights, 8 side/front-fill fixtures, 24 × 380 W LED moving-head profile fixtures for top light, 18 LED PAR fixtures for backlight, 12 LED wash fixtures for side light, and 3 × 1,200 W discharge followspots. Total luminous flux is approximately 1,176,000 lm.
Illuminance is calculated using the utilization-factor method: E=Φ·U·M/A. The utilization factor U is 0.40 and the maintenance factor M is 0.78, accounting for LED depreciation and dust accumulation on fixtures. The calculated stage area is 14.0 m wide at the proscenium × 8.0 m deep = 112 m². The theoretical value at full output is 3,276 lx. With practical zoning and dimming levels, the calculated values for the five zones are 3,060–3,180 lx. Compared with measured values of 3,041–3,133 lx, the calculations are 1.4%–3.3% higher, consistent with the selected U and M values.
The spread is only 92 lx (3%), indicating good consistency across the five lighting zones. Twelve front lights plus ten auxiliary fixtures cover the full 14 m proscenium width; 24 top lights in two rows cover the 8 m stage depth; and side/front-fill and side lights on both sides supplement the edges. There is no step change in illuminance between the center and edge zones. This small spread is determined by fixture distribution density, not simply by dimming adjustments.
Color temperature follows a separate control path. Fixtures were procured with a single 5,600 K setting, with batch color tolerance controlled to SDCM≤3 and unified dimming-curve calibration to avoid color shifts at low output. The eight measured points ranged from 5,667 to 5,717 K, averaging 5,697 K—97 K above the design target but still within the ±150 K tolerance. The 50 K spread is approximately one-sixth of the tolerance band, providing a consistent basis for white balance across multiple cameras.

Figure D-05 | Stage Lighting Layout: Front Light, Side/Front Fill, Top Light, Backlight, Side Light, Followspots and Fixture Counts

Figure D-06 | Comparison of Measured Stage Illuminance and Color Temperature: Five Illuminance Zones and Eight Color-Temperature Points
The first step in sightline design is to define the viewing reference point. This project uses the center of the proscenium line plus the stage-surface elevation (stage surface +900 mm), the preferred reference under the applicable practice and requiring no offset justification. The proscenium is assumed to be 14.0 m wide and 7.0 m high—a reasonable assumption for a 400 m² variety studio with an 11 m floor height. The first-row eye position is 4,000 mm from the proscenium, row spacing is 1,000 mm, and the 10 rows are staggered.
The row-by-row calculation gives non-negative C-values (sightline clearance after deducting 120 mm from eye level to the top of the head). After construction rounding to the nearest 10 mm, the values range from 2.0 to 30.0 mm. The basis should be clarified: the seating rake uses the minimum rise that just clears the head in the row ahead. Therefore, the row at each new step has a C-value close to 0–7 mm, while the second row on the same level returns to 25–30 mm because its sightline is steeper, creating a sawtooth pattern. This is an inevitable result of minimum-rise design, not a calculation error for an individual seat. If checked against a fixed-theatre criterion of C≥50 mm, every row would need its own step and the rear floor would need to rise another 200–400 mm. This studio uses stepped platforms with motorized seats and is not primarily a fixed-seating theatre. The design therefore prioritizes “unobstructed views + camera and jib-crane circulation,” reserving flexibility for the front mobile seating area and rear main audience area. If greater comfort is required at the construction-drawing stage, a 20–30 mm topping can be added to the existing steps without changing the row layout or screen conclusions. In the actual layout, the first two rows remain at floor level; steps begin at Row 3, with one step for every two rows. The maximum single rise is 410 mm. The rear-row eye height is 2,600 mm and floor level 1,450 mm; rear viewing distance is 13.0 m and horizontal viewing angle 56.6°. The longitudinal aisle slope is 1:2.4, steeper than 1:6, so steps rather than a ramp are required.
The first row has a horizontal viewing angle of 120.5°, slightly exceeding the 120° upper limit. This is a geometric consequence of a 14 m proscenium and a 4 m first-row distance, not a seating-layout error: the closer the first row, the wider the subtended angle. The design response is not to narrow the proscenium, but to make the 4.0–8.0 m zone a flexible area where motorized seats can be retracted to provide front camera positions and jib-crane circulation. The main fixed viewing area begins at Row 6, 9.0 m from the proscenium.
The main-screen dimensions are calculated backward from the last row. The rear row is 13.80 m from the screen (13.0 m plus a 0.8 m screen setback from the proscenium line). To achieve a vertical screen viewing angle of at least 15° from the last row, screen height must be at least 2×13.80×tan7.5°=3.63 m. Using 500 mm cabinet modules, the selected size is 7,000×4,000 mm (14 columns × 8 rows, 112 cabinets), close to a 16:9 aspect ratio. Verification gives a vertical viewing angle of 16.5° and horizontal angle of 28.5° from the last row, meeting the requirement.
Pixel pitch determines the closest distance at which the image can be resolved; it does not determine the maximum viewing distance. P2.6 corresponds to a minimum clear viewing distance of 2.60 m, shorter than the 4.80 m distance from the first row to the screen, and is therefore adequate. Broadcast-grade 4K recording must also consider moiré. A smaller pixel pitch and higher screen fill factor reduce the likelihood of low-frequency beat patterns between camera sampling and the LED pixel grid. At viewing distances of 4.8–13.8 m, P2.6 is expected to avoid visible moiré and scan lines. Moving to P1.5 would increase cost and cooling-fan noise; fan noise could directly raise the background-noise level and undermine the NR-22 result.
Table 4 | Row-by-Row Sightlines and C-Values (Construction Rises Rounded to 10 mm)
Row | Distance from proscenium (m) | Floor elevation (mm) | Rise (mm) | Eye height (mm) | Horizontal viewing angle (°) | Depression angle (°) | C-value (mm) |
1 | 4.00 | 0 | 0 | 1,150 | 120.5 | 3.6 | — |
2 | 5.00 | 0 | 0 | 1,150 | 108.9 | 2.9 | — |
3 | 6.00 | 310 | 310 | 1,460 | 98.8 | 5.3 | 3.3 |
4 | 7.00 | 310 | 0 | 1,460 | 90.0 | 4.5 | 30.0 |
5 | 8.00 | 660 | 350 | 1,810 | 82.4 | 6.4 | 2.5 |
6 | 9.00 | 660 | 0 | 1,810 | 75.8 | 5.7 | 27.8 |
7 | 10.00 | 1,040 | 380 | 2,190 | 70.0 | 7.3 | 2.0 |
8 | 11.00 | 1,040 | 0 | 2,190 | 64.9 | 6.6 | 25.5 |
9 | 12.00 | 1,450 | 410 | 2,600 | 60.5 | 7.9 | 6.7 |
10 | 13.00 | 1,450 | 0 | 2,600 | 56.6 | 7.3 | 28.5 |
Note: Rises are rounded to the minimum feasible values. C≥0 indicates visibility without obstruction by the row ahead. Thus, the first row at each new step is close to 0, while the second row on the same level returns to 25–30 mm. The first-row horizontal viewing angle is 120.5°, slightly above the 120° limit; therefore, the 4.0–8.0 m first-row zone is designed as a retractable flexible area.

Figure D-07 | Longitudinal Section: Row-by-Row Sightline Rises, C-Values, Screen and Lighting-Bar Elevations
Fixture loads are first established: PAR light 16 kg, wash light 18 kg, profile light 21 kg, imaging/profile spotlight 22 kg and followspot 45 kg, plus 3.0 kg/m for cables and hooks/accessories. With all seven lighting bars fully equipped, the load per bar ranges from 227 to 512 kg, and the total studio load is 2,881 kg (28.26 kN). The load combination is 1.3G+1.5Q, the deflection limit is L/200, and verification uses the most unfavorable simply supported single-span envelope after failure of a suspension point.
The original proposal used SQ400 (400×400 aluminum truss) for all seven bars. At a full 16 m span, T1 deflection was 74.97 mm (L/213), with 94% utilization; T3 and T4 deflection was 72.96 mm (L/219), with 91% utilization. Although these values passed, the margin was below 10%. Additional fixtures or cables, or replacement with heavier profile fixtures, could consume the remaining margin. Considering the L/300 alignment requirement for profile fixtures, the five top-light and front-light bars were upgraded to SQ520 (520×520).
After the upgrade, T1 deflection was 47.7 mm (L/335), with 60% utilization; T2 was 41.8 mm and 52%; T3/T4 were 46.6 mm and 58%; and T5 was 39.9 mm and 50%. The rear backlight bar T6 (12 m) and followspot bar T7 (8 m) remained SQ400, with deflections of 19.2 mm and 5.3 mm and utilization rates of 32% and 13%, respectively. Maximum utilization across the studio is 60%, leaving 40% capacity for future modifications.
There are 28 suspension points, with four points supporting each lighting bar. The maximum reaction at an individual point is 1.93 kN (193 kg). Each point uses a 1,000 kg electric hoist, giving 19.7% utilization. Reactions at multiple suspension points are not evenly distributed; systems with more than three points are statically indeterminate and must be leveled using adjustable hoists. A non-uniformity factor of 1.15 is included in the design margin. One requirement must be emphasized: suspension points must connect to the grid’s suspension beams or main members. Connecting to secondary members, deck plates or the middle of a beam bay is geometrically invalid, regardless of how accurately the load is calculated. The client must provide structural drawings confirming whether the grid steelwork is single- or double-layer, whether it is fully decked or uses catwalks, and the arrangement of access routes, so suspension elevations and hoist travel allowances can be finalized.
Table 5 | Lighting Truss Verification and Suspension-Point Reactions
Bar | Model | Span (m) | Total weight (kg) | Deflection (mm) | L/ ratio | Maximum utilization | Suspension reaction (kN), edge/center |
T1 | SQ520 | 16 | 512 | 47.7 | 335 | 60% | 0.96/1.93 |
T2 | SQ520 | 16 | 448 | 41.8 | 383 | 52% | 0.84/1.68 |
T3 | SQ520 | 16 | 500 | 46.6 | 343 | 58% | 0.94/1.88 |
T4 | SQ520 | 16 | 500 | 46.6 | 343 | 58% | 0.94/1.88 |
T5 | SQ520 | 16 | 428 | 39.9 | 401 | 50% | 0.80/1.61 |
T6 | SQ400 | 12 | 266 | 19.2 | 624 | 32% | 0.50/1.00 |
T7 | SQ400 | 8 | 227 | 5.3 | 1,501 | 13% | 0.43/0.85 |
Total | — | — | 2,881 | — | — | 60% | 1.93 (maximum) |
Deflection is checked using the most unfavorable simply supported single-span envelope after loss of a suspension point. Suspension reactions are estimated from tributary length multiplied by a 1.15 non-uniformity factor; adjustable hoists must be used for leveling and the results verified by measurement.

Figure D-08 | Lighting Truss Plan, Suspension-Point Identification and Reaction Table
The main purpose of this calculation review is to consolidate the preceding sections into one comparison table. The three columns are presented side by side, with each item assessed and “design margin” distinguished from “not covered by measurement.”

Figure D-09 | Third-Party Test Layout: Reverberation Points P1–P7, Background Noise, Five Illuminance Zones, Eight Color-Temperature Points and Sound-Insulation Points
There are three deliberate design margins. Reverberation was balanced at 0.70 s, compared with the measured 0.66 s (approximately 6% absorption margin). Background noise was committed at NR-30, tested against NR-25 and measured at NR-22 (an 8 dB progression across the three levels). The acoustic door has Rw 41 against a threshold of 40 (2 dB margin), while the vestibule and seals raised the on-site value to 48.0 dB(A). These are not calculation errors; the operating points were intentionally placed inside the acceptance limits.
Four items were not covered by the measurements: color-rendering index Ra, RASTI/speech intelligibility, sound-field non-uniformity and floor impact sound. Since the report contains no readings for these items, this article gives design calculations only: Ra is controlled through a continuous spectrum and SDCM≤3; the RASTI target is >0.65; sound-field non-uniformity is allowed for under GB/T 28049-2011; and calculated Ln,w is 48.0 dB. Each is clearly marked “not measured; no inference made.” These items can be added to the comparison table during future retesting using the same measurement points and operating conditions.
Table 6 | Three-Way Comparison of Design Values, Test Criteria and Measured Values
Parameter | Standard reference | Tender design value | Test criterion | Measured value | Assessment and notes |
Reverberation time, 500–1,000 Hz | GY/T 5086-2012; GB/T 50076-2013 | 0.70±0.1 s | 0.65±0.1 s | 0.66 s | Design calculation 0.699 s; measured value is within the test criterion. |
Separate 500 Hz/1,000 Hz bands | GB/T 50076-2013 (interrupted-noise-source method) | — | — | 0.64/0.68 s | Design values 0.699/0.697 s; compared by frequency band. |
Background noise | GB 50118-2010; GY/T 5086-2012 | NR-30 | NR-25 | NR-22 | Calculated NR-21; 3 dB better than the test criterion. |
Acoustic door sound level difference | GB/T 19885-2005 | 40 dB(A) | 40 dB(A) | 48.0 dB(A) | Element Rw 41 / composite 42; 8 dB above threshold. |
Acoustic window sound level difference | GB/T 19885-2005 | 50 dB(A) | 50 dB(A) | 51.1 dB(A) | Initial construction estimate of 47 dB was insufficient; laminated glass and pane angle brought it into compliance. |
Acoustic wall sound level difference | GB/T 19885-2005 | 50 dB(A) | 50 dB(A) | 50.2 dB(A) | Composite apparent value 52 dB; doors and windows are the controlling elements. |
Stage illuminance (5 zones) | GY 5045-2006; GB/T 50034-2024 | ≥1,200 lx | ≥2,000 lx | 3,041–3,133 lx | Calculated 3,060–3,180 lx, 1.4%–3.3% higher. |
Color temperature (8 points) | GY 5045-2006 | 5,600±150 K | 5,600±150 K | 5,667–5,717 K (average 5,697 K) | Within tolerance band; spread 50 K. |
Color-rendering index Ra | GY 5045-2006 | ≥95 (continuous spectrum) | Not specified | Not measured | Not measured in report; no inference made. |
RASTI | GY/T 5086-2012 | >0.65 | Not specified | Not measured | Not measured in report; no inference made. |
Sound-field non-uniformity | GB/T 28049-2011 | As designed | Not specified | Not measured | Not measured in report; no inference made. |
Floor impact sound Ln,w | GB 50118-2010 | Design-controlled | Not specified | Not measured | Design calculation 48.0 dB (ΔLw 29.9); not a measured result. |
The three columns use different criteria and cannot be used to determine whether one another is “over the limit.” The meaningful comparisons are whether measured results fall within the test criteria and whether deviations between design calculations and measured values can be explained.
Finally, return to the one-time contractual acceptance on October 28, 2026. The acceptance report addresses procedures and checklists; the test report addresses physical performance; and this calculation review answers a third question: how the values were calculated at the design stage, where margins were retained and which items have not yet been measured. Together, the three documents form a complete, verifiable and traceable delivery record.
In accordance with GY 5045-2006, Design Code for Television Studio Lighting Systems, and the project design standards, the lighting system focuses on the following parameters: at camera aperture 5.6, combined vertical illuminance in the front-light area (at 5,600 K) of at least 1,200 LUX; studio color temperature of 5,600±150 K; and color-rendering index of at least 95 with a continuous spectrum. The system also meets 4K shooting illuminance requirements, with even lighting across the stage and audience areas to ensure consistent, natural skin tones and clothing colors in HD/UHD recordings. After delivery, third-party testing measured stage-area illuminance of 3,041–3,133 lx and an average color temperature of 5,697 K; both were assessed as “meeting the requirements.” See Section 3 for the measurement criteria and data.
The studio’s acoustic design targets are a reverberation time of 0.70±0.1 s, a noise rating of NR-30 and a Rapid Speech Transmission Index (RASTI) above 0.65. Floating/resilient construction, acoustic doors and windows, absorptive/diffusive structures and equipment-room noise control are used to suppress echoes, flutter echoes and low-frequency hum, maintaining clear, intelligible speech and good fullness throughout the room while providing a suitable monitoring environment. Third-party testing used the interrupted-noise-source method in the unoccupied room and measured 0.66 s in the 500–1,000 Hz octave band, background noise NR-22, and sound level differences of 48.0/51.1/50.2 dB(A) for the acoustic door/window/wall. See Section 3 for details.
The combination of a fascia screen, main screen, side screens and floor screen allows the same space to switch rapidly between visual styles for interviews, public affairs programs, variety shows and press conferences. LED content is linked with lighting, machinery and audio, while scenic elements reinforce the identity and stage presentation of each program format.
Line-array main speakers combined with zoned fill speakers help control sound-energy directivity and reduce interference from early reflections. They provide an even sound-pressure distribution in a relatively large audience area, balancing the high dynamic range required for performances with the speech intelligibility needed for conferences and presentations.
Centralized control integrates lighting, video, audio, machinery and cameras on one platform. Program automation standardizes and streamlines production, while the station-wide architecture monitoring platform provides unified interfaces and resource management, connecting the studio systems. Directors and duty operators can recall preset scenes with a single command from one terminal, avoiding the complexity and human error associated with adjusting multiple systems separately.
Lighting suspension, stage machinery, power distribution and grounding are designed with safety margins and redundancy. Load-bearing components have adequate safety factors; electrical capacity includes reserve; power and signal cables are routed separately and grounded independently. Compliant low-smoke, halogen-free cables are used throughout, with UPS and emergency switches to support reliable broadcast-grade operation. LED technology is used for lighting and displays to reduce heat generation and air-conditioning loads, supporting fire safety and environmental objectives.
In addition to production and live-broadcast safety, system integration considers flexible, convenient and fast signal routing, with orderly cable routing and clear identification. Professional acoustic simulation software is used to support the design, and an indoor reverberation-time calculation report is prepared. Simulation results must meet the technical requirements of the audio and acoustic systems, including maximum sound-pressure level, steady-state sound-field non-uniformity, reverberation time and RASTI. Detailed system diagrams, cable-code schedules, rack-location drawings and power-system diagrams are also provided.
Existing rooms in broadcasting facilities are often located inside larger buildings and can be affected by air-conditioning systems, elevators, equipment rooms and external traffic noise. The solution is to conduct an acoustic survey to identify noise sources, then apply sound-insulating walls and doors (sound insulation >40 dB), floating floors, resilient hangers and silencers as an integrated treatment. Adjacent spaces receive sound and vibration isolation to keep background noise within NR-30.
Lighting dimmers, LED drivers, power amplifiers and motor controllers are all potential sources of interference. Solutions include separate cable trays for power and signal circuits, adequate spacing between signal and power cables, independent star grounding, optically isolated dimmer outputs, balanced audio transmission, and shielding for LED-screen power and control systems to prevent hum, ripple artifacts and signal packet loss.
Program production and live broadcasting leave no room for trial and error. Critical equipment and signal paths therefore use primary/backup redundancy, such as main and backup mixing consoles and signal routes. Standard operating procedures and emergency plans are built around the computerized lighting console. Before handover, multiple rounds of integrated commissioning and loaded stress testing verify stable, seamless transitions between scenes.
Lighting fixtures, loudspeakers, LED screens and stage-machinery suspension points all require elevated installation. Before construction, the load capacity of the existing beams and slabs is checked. Independent steel catwalks and suspension beams are added where necessary. Elevated work uses scaffolding or lifting platforms together with safety harnesses. Load-bearing components undergo flaw detection or load testing, with written acceptance records.
The following photographs show the completed 400 m² variety studio at Qingyuan Radio and Television Station and illustrate the integrated audiovisual results of the systems.

Figure: Variety studio stage area, including the fascia LED text “Qingyuan Radio and Television Station,” main LED screen, line-array speakers and stage lighting array.

Figure: Variety studio audience area, showing tiered red audience seats, an LED background screen and overhead line-array speakers.

Figure: The main stage LED screen displaying live content, coordinated with lighting and scenic elements to create a variety-show setting.

Figure: Production control room, with centralized control console, monitoring screens and a viewing window overlooking the studio, supporting operation of the centralized control system.

Figure: Actual stage lighting arrangement, including moving-head lights, PAR lights and truss-mounted fixture arrays.

Figure: Motorized audience seating area with flexible red seating layouts for variety shows, interviews and press conferences.
A: A variety studio must support more than meetings and presentations. It must accommodate interviews, public affairs programs, quiz competitions, variety shows and press conferences for television production. It has broadcast-grade requirements for building acoustics (reverberation time 0.70±0.1 s and NR-30), television lighting (illuminance ≥1,200 LUX, color temperature 5,600 K and color-rendering index ≥95), sound reinforcement, LED displays and centralized control. It must also support rapid scenic changes between program formats, making it fundamentally different from an ordinary meeting room.
A: Television images are produced using multiple camera positions. At a camera aperture of 5.6, combined vertical illuminance in the front-light area (at 5,600 K) of at least 1,200 LUX supports 4K production. A consistent color temperature of 5,600±150 K helps prevent color differences between camera positions. A color-rendering index of at least 95 with a continuous spectrum helps reproduce skin tones and clothing colors accurately, avoiding dull or shifted colors. In this project, third-party report SSD202600259 measured stage-area illuminance of 3,041–3,133 lx and an average color temperature of 5,697 K across eight points (requirement: 5,600±150 K); both results were assessed as “meeting the requirements.” The report did not measure color-rendering index Ra, so no numerical inference is made. See Section 3 for the testing criteria.
A: A reverberation time of 0.70±0.1 s is a short-to-medium decay time that supports speech clarity. An NR-30 noise-rating curve represents a very low background-noise level, helping prevent unwanted noise from being picked up by microphones. RASTI >0.65 quantifies speech intelligibility. Together, these targets support good listening quality for both quiet dialogue and music. Note that these are design targets in the tender’s technical specifications. The customer design requirements used for third-party testing were 0.65±0.1 s and NR-25; measured results were 0.66 s in the 500–1,000 Hz octave band and NR-22, respectively, and both met the stated requirements. See Section 3.
A: The centralized control system integrates lighting, video, audio, machinery and cameras on one platform, and provides program automation and station-wide architecture monitoring. Directors and duty operators can recall preset scenes from a single terminal, connecting systems and sharing resources. This improves recording efficiency and lowers the operational burden.
A: Motorized seats allow the audience layout to be adjusted to each program format. They can be retracted to enlarge the front stage area for variety shows, or deployed to form an audience seating area for interviews, public affairs programs and press conferences. This improves space utilization and makes the studio more adaptable to different production scenarios.
A: The computerized lighting console is the “brain” of the stage lighting and machinery system. It patches fixtures, programs scenes and controls lighting in real time, directly affecting lighting quality and live-broadcast reliability. The tender documents identified it as a core product (marked with △) and treated bidders offering the same brand as one bidder, highlighting its central role in the integrated audiovisual system.
A: The main standards referenced for design, construction and acceptance include GY 5070-2013, Code for Construction and Acceptance of Television Studio Lighting Systems; GB/T 28049-2011, Code for the Design of Sound Reinforcement Systems in Halls and Sports Venues; GY/T 5086-2012, Acoustic Design Code for Radio and Television Recording Studios and Television Studios; GY 5045-2006, Design Code for Television Studio Lighting Systems; and GB/T 4959-2011, Measurement Methods for Sound Reinforcement Characteristics in Halls. Together, they cover lighting, audio, acoustics, electrical systems and fire safety. The organization and procedure for contractual acceptance also followed Finance Treasury [2016] No. 205, Finance Treasury [2021] No. 22 and the contract. Third-party acoustic and lighting testing followed GB/T 50076-2013, GB/T 50034-2024, GB/T 19885-2005 and the assessment rules in CNAS-GL015:2022. The project completed one-time contractual acceptance in October 2026; the final conclusion was qualified, and all 13 acceptance items passed.
A: The project completed one-time contractual acceptance at Qingyuan Radio and Television Station’s new facility on October 28, 2026. The acceptance report was marked “Accepted,” with a final conclusion of “Qualified” and “None” entered under “Outstanding issues and recommendations for improvement.” All 8 acceptance categories and standards in Section 9.5 and all 13 acceptance items in Section 9.7—including equipment delivery, installation and commissioning, the seven major systems, auxiliary-room renovation, technical-document handover, operator training and after-sales service commitments—were judged qualified. No outstanding issue affecting acceptance was found. The purchaser, supplier, supervising party and acceptance organizer signed and sealed the report. Four copies were issued, one for each party.
A: The project delivered seven integrated systems—lighting and machinery, audio, large-screen display, centralized control, air conditioning and power distribution, motorized seating and auxiliary-room fit-out, and acoustics—all operating together in one studio. A single contractual acceptance made it easier to verify the overall functions and documentation. The purchaser appointed Guangdong Hexin Tendering Agency Co., Ltd. to organize acceptance, with Guangzhou Nanyue Engineering Construction Supervision Co., Ltd. as supervising party. The process followed Finance Treasury [2016] No. 205, Finance Treasury [2021] No. 22 and the contract, with goods checked item by item against the Contract Procurement List attached to the contract. The acceptance team included multiple parties and professional technical personnel, helping avoid a situation in which the same party acts as both player and referee.
A: According to test report SSD202600259 issued by the South China National Center of Metrology (Guangdong Institute of Metrology), measurements were taken under GB/T 50076-2013 using the interrupted-noise-source method at seven points in the unoccupied room. The average was 0.64 s at 500 Hz and 0.68 s at 1,000 Hz, giving an octave-band reverberation time of 0.66 s across 500–1,000 Hz (customer requirement for this test: 0.65±0.1 s). With equipment and air conditioning off and surrounding operations normal without abnormal interference, background noise was NR-22 (requirement: NR-25). Sound level differences for the acoustic door, window and wall were 48.0, 51.1 and 50.2 dB(A), respectively, exceeding the corresponding design thresholds. All results were assessed as “meeting the requirements.” See Section 3.
A: Three points are essential. First, define the criteria: include design targets (reverberation time, background-noise NR, illuminance, color temperature and color-rendering index), measurement methods and applicable standards in the contract. Second, specify the test report: require an accredited third-party metrology organization to issue measured results, and confirm that the report language, metrology body information and measurement-point layout are traceable for local verification. The South China National Center of Metrology report SSD202600259 from this project provides a reference. Third, confirm delivery details, including compatibility with local power supply systems (voltage and frequency vary across South American countries), export packaging, on-site installation guidance and remote integrated commissioning. For inquiries, contact WhatsApp: +1 3142036465 or Email: saijia.avl@gmail.com.
A: Yes. The same report, SSD202600259, measured the stage area at customer-designated points and a height of 1.5 m. Average illuminance across the center zone and the two zones on each side ranged from 3,041 to 3,133 lx. The customer design requirement was “vertical illuminance of the combined studio lighting of at least 2,000 lx at camera aperture 5.6.” Readings at eight color-temperature points ranged from 5,667 to 5,717 K, with an average of 5,697 K, within the 5,600±150 K range. Both illuminance and color temperature were assessed as “meeting the requirements.” Note that the report did not measure Ra, RASTI or other unreported parameters, so no numerical inference is made. The tender design targets and test criteria are different and are discussed separately in Section 3.
A: The core of a variety studio is the user experience. Building acoustics—sound insulation, absorption, background noise and reverberation time—are the foundation of audio and image quality. Saijia conducts acoustic surveys and simulations at the proposal stage, resolving noise and sound-quality issues before focusing on equipment configuration.
A: Adequate illuminance does not automatically mean good images. Front-light illuminance ≥1,200 LUX, color temperature of 5,600±150 K and color-rendering index ≥95 with a continuous spectrum are key to 4K production. Lighting should be designed systematically in accordance with GY 5045-2006 rather than by simply adding more fixtures.
A: Broadcast applications have higher requirements for refresh rate, grayscale, color consistency and brightness matching. Otherwise, scan lines, moiré patterns or flicker during recording may occur. Cooling-fan noise from the screen can also raise background noise, so the full set of factors must be evaluated during selection.
A: Higher sound-pressure levels do not necessarily mean better sound quality. Speaker placement, sound-field simulation, delay and equalization determine clarity and uniformity. Simply increasing the number of speakers may instead cause interference and feedback.
A: Nothing is trivial in live broadcasting. Critical signal paths should have primary/backup redundancy. Multiple rounds of integrated commissioning and loaded testing must be completed before handover, together with emergency procedures, to support error-free transmission.
A: Acceptance of a variety studio goes far beyond a power-on demonstration. The acceptance report for this project listed eight acceptance categories: goods list, technical performance, operating status and installation/commissioning, quality certificates, after-sales commitment letter, safety standards, and contractual delivery time/location/method. Technical-document handover, operator training and after-sales service commitments were also listed as separate acceptance items. Only after all 13 items were individually judged qualified was the final qualified conclusion issued. If acceptance checks only whether equipment powers on, missing documentation, inadequate training and unsupported after-sales commitments may not become apparent until the studio enters operation.
A: Tender documents can specify reverberation time, NR curves, illuminance and color temperature, but on-site testing—with measurement points, operating conditions and instrument traceability records—is needed to prove that the targets have been achieved. In addition to contractual acceptance, this project obtained test report SSD202600259 from the South China National Center of Metrology (Guangdong Institute of Metrology). It records a reverberation time of 0.66 s, background noise NR-22, acoustic door/window/wall sound level differences of 48.0/51.1/50.2 dB(A), illuminance of 3,041–3,133 lx and average color temperature of 5,697 K, together with conditions such as an unoccupied room, closed doors/windows, air conditioning off, and microphone and measurement-point heights. Without this step, it can be difficult to determine whether later complaints such as color shifts, muffled sound or air-conditioning noise entering microphones result from design, construction or operating conditions.
A: Design specifications use one set of criteria, while local acceptance requires measured records that can be understood and independently verified. For international procurement, the contract should define the test-report language (Chinese and English), the issuing organization’s qualifications and traceability, measurement methods, measurement-point layout and assessment basis. Otherwise, the parties may be unable to compare results during acceptance, and dispute costs can far exceed testing costs. This project provides a reference: measurements were commissioned from the South China National Center of Metrology (Guangdong Institute of Metrology), and the report was archived with the acceptance documents.
The main national and industry standards referenced for the design, construction and acceptance of this project (organized by system and primarily drawn from the technical clauses of the project tender), together with the government procurement policy documents governing contractual acceptance and the measurement standards and decision rules used for third-party testing, are listed below:
Standards and Reference Table
Category | Standard No. | Standard title |
Stage lighting | GY 5070-2013 | Code for Construction and Acceptance of Television Studio Lighting Systems |
Stage lighting | GY 5045-2006 | Design Code for Television Studio Lighting Systems |
Stage lighting | GB 7000.217-2008 | Luminaires—Particular Requirements—Luminaires for Stage Lighting, Television, Film and Photographic Studios (Indoor and Outdoor) |
Stage lighting | GB 7000.1-2015 | Luminaires—General Requirements and Tests |
Stage lighting | GB/T 7002-2008 | Photometric Testing of Floodlighting Luminaires |
Stage lighting | GB/T 17743-2007 | Limits and Methods of Measurement of Radio Disturbance Characteristics of Electrical Lighting and Similar Equipment |
Lighting control | WH/T 32-2008 | DMX512-A Lighting Control Data Transmission Protocol |
Sound reinforcement | GB/T 28049-2011 | Code for the Design of Sound Reinforcement Systems in Halls and Sports Venues |
Sound reinforcement | GB/T 4959-2011 | Measurement Methods for Sound Reinforcement Characteristics in Halls |
Sound reinforcement | GB/T 6278-2012 | Sound System Equipment—General |
Sound reinforcement | GB/T 10240-1988 | Program Source Editing and Production Specifications for Subjective Sound-Quality Evaluation of Electroacoustic Products |
Sound reinforcement | GYJ 25-1986 | Acoustic Performance Specifications for Sound Reinforcement Systems in Halls |
Building acoustics | GY/T 5086-2012 | Acoustic Design Code for Radio and Television Recording Studios and Television Studios |
Building acoustics | GY 5022-2007 | Code for Measurement of Reverberation Time in Radio and Television Broadcasting (Studio) Rooms |
Building acoustics | GB/T 50076-2013 | Code for Measurement of Reverberation Time in Rooms |
Building acoustics | GB 50118-2010 | Code for Design of Sound Insulation of Civil Buildings |
Building acoustics | GY/T 5043-2013 | Indoor Environmental Requirements for Technical Rooms in Radio and Television Centers |
Structured cabling | GB/T 50311-2016 | Code for Engineering Design of Generic Cabling Systems |
Building electrical | GB 50168-2018 | Code for Construction and Acceptance of Cable Lines in Electrical Installation Engineering |
Building electrical | GB 50016-2014 | Code for Fire Protection Design of Buildings |
Building electrical | GB 50034-2004 | Standard for Lighting Design of Buildings |
Building electrical | GY/T 5061-2015 | Lighting Design Code for Technical Rooms in Radio, Film and Television Engineering |
HVAC | GB 50736-2012 | Design Code for Heating, Ventilation and Air Conditioning of Civil Buildings |
Acceptance management | Finance Treasury [2016] No. 205 | Guiding Opinions of the Ministry of Finance on Further Strengthening Government Procurement Requirements and Contract Performance Acceptance Management |
Acceptance management | Finance Treasury [2021] No. 22 | Measures for the Administration of Government Procurement Requirements |
Test and measurement | GB/T 50076-2013 | Code for Measurement of Reverberation Time in Rooms |
Test and measurement | GB/T 19885-2005 | Acoustics—Measurement of Sound Insulation Performance of Enclosures—Laboratory and Field Measurements |
Lighting testing | GB/T 50034-2024 | Standard for Lighting Design of Buildings |
Conformity assessment | CNAS-GL015:2022 | Guidelines for Decision Rules and Statements of Conformity (Clause 6.2.1) |
Guangzhou Saijia Acoustic & Lighting Engineering Co., Ltd. has long served broadcasting and television stations, integrated media centers, cultural-tourism projects, government bodies and public/private institutions. The company provides architectural acoustic fit-out and integrated audiovisual systems, equipment supply, installation, commissioning and operation/maintenance services for variety studios, news studios, lecture halls and multipurpose halls. Its key overseas market is South America.
The 400 m² variety studio system project at Qingyuan Radio and Television Station (interior fit-out, lighting, audio, acoustics and stage machinery) is built on a broadcast-grade acoustic environment and integrates stage lighting and machinery, professional audio, large LED displays, centralized control, air conditioning and power distribution, motorized seating and associated facilities, and building acoustics. It creates a modern audiovisual space for interviews, public affairs programs, variety shows, press conferences and other program formats. Through systematic design, detailed construction and multiple rounds of integrated commissioning, the project provides a replicable example for audiovisual system development at municipal-level broadcasting organizations. The project completed one-time contractual acceptance in October 2026, with a final conclusion of “Qualified”; all 13 acceptance items passed, with no outstanding rectification items, completing the full process from design and construction through integrated commissioning to acceptance and delivery. Test report SSD202600259, issued by the South China National Center of Metrology (Guangdong Institute of Metrology), further verifies the performance through measured data: reverberation time of 0.66 s in the 500–1,000 Hz octave band, background noise NR-22, acoustic door/window/wall sound level differences of 48.0/51.1/50.2 dB(A), stage-area illuminance of 3,041–3,133 lx and average color temperature of 5,697 K. All results met the customer’s technical requirements, giving this case both a verifiable procedural conclusion and measured performance evidence.
For more information about audiovisual system solutions for variety studios, news studios, lecture halls and multipurpose halls, please contact Guangzhou Saijia Acoustic & Lighting Engineering Co., Ltd.
Guangzhou Saijia Acoustic Lighting Engineering Co., Ltd.|WhatsApp: +1 3142036465|Email: saijia.avl@gmail.com|Address: Room 615, No. 135, Huangyuan Road (Building 3), Baiyun District, Guangzhou
Overseas Service Areas
Focus region: South America
Countries: Brazil, Argentina, Colombia, Chile, Peru, Venezuela
Guangzhou Saijia Acoustic Lighting Engineering Co., Ltd. targets radio and television stations, integrated media centers, cultural venues, and enterprises and institutions in South American countries and regions. It provides architectural acoustic decoration and acousto-optical TV listening system integration, equipment supply, installation and commissioning, acceptance delivery and operation and maintenance services for variety show studios, news studios, lecture halls and multi-functional halls. It supports remote solution deepening, localized project coordination and multi-lingual technical document delivery.
For the calculation process, parameter definitions, and drawings from the design phase, please refer to the attached "Design Calculation Report."