Reverberation time in a concert hall is controlled by balancing three things: room volume, surface absorption and diffusion, and adjustable acoustic elements. You set a target for the type of music, then predict, build and measure against it. At Guangzhou Saijia Acoustic & Lighting Engineering Co., Ltd. (SJAVL), we have delivered turnkey venue projects for 26 years. Most acoustic problems we are called in to fix began as a missed number in the first design stage.

RT60 is the time it takes for sound to fall by 60 dB after the source stops. It is the most basic measure of how "live" a hall feels.
Wallace Sabine set the foundation around 1898. He found that decay time rises with room volume and falls with absorption, and he expressed this as T = 0.161 V/A. V is volume in cubic meters and A is total absorption in square meters.
He also found that good concert halls ran about 2–2.25 seconds. Shorter times sounded too "dry." Lecture rooms worked best at just under 1 second.
Why it matters:
- Too long: notes blur and speech becomes unclear.
- Too short: music sounds thin and lacks sustain.
- Just right: notes blend and bloom without losing clarity.
Always set the target before you draw the hall. A symphonic hall needs a mid-frequency RT60 of about 1.8–2.2 seconds at 500–1000 Hz. Published guidance puts chamber music at about 1.4–1.7 seconds and opera at about 1.2–1.5 seconds.
| Use | Typical mid-frequency RT60 |
|---|---|
| Symphonic orchestra | 1.8–2.2 s |
| Chamber music | 1.4–1.7 s |
| Opera | 1.2–1.5 s |
| Amplified music | about 1.0 s |
| Speech | 0.4–1.0 s |
Figures are drawn from. Boston Symphony Hall, an acoustic benchmark, measures about 1.85 seconds occupied.
Our experience: clients often ask for "the best RT60." No single best value exists. The right value depends on hall volume, music type, audience size, seating, stage layout and the character the owner wants. We write this down in the brief before any design begins.
Volume sets the maximum reverberation. A symphonic hall typically needs 8–11 m³ per seat. If the volume is too small, no finish will rescue the result.
Audience and seating are the largest absorbers in the room. Heavy curtains, panels and treated walls add to this. Because an empty hall differs sharply from a full one, we design upholstered seats to absorb about the same as a seated person. Rehearsals and commissioning then stay representative.
Hard, shaped surfaces return energy without killing the sound. Diffusion keeps a hall lively while avoiding echoes. For concert spaces, many designers use targeted absorption and rely on diffusion for the rest.
Two materials with similar NRC ratings can behave very differently at specific frequencies. Untreated rooms often show very different RT60 at low and high frequencies. We specify absorption band by band, not by a single rating.
Variable acoustics let one hall serve many events. This is now standard in multi-use venues.
The simplest and most affordable method is retractable absorbing banners or heavy curtains. Deploy them to reduce reverberation, or retract them to increase it.
- Motorized banners: adjustable spacing from the wall and between fabric layers controls how much absorption you get.
- Curtain tracks on side walls: these lower reverberation for amplified events and brass band concerts.
- Reverberation chambers: wall panels open in steps to couple extra volume to the hall.
- Roller banner systems: these can be up to 4.5 m wide and suit chamber music, choir, electronic and conference use.
Acousticians specify the fabric type and weight, and the air gap behind it. The goal is that the venue operator can adjust the room simply.
SJAVL tip: treat the motors, tracks and controls as part of stage machinery and intelligent control, not as an afterthought. We integrate them with the building control system so a technician can recall presets such as "Symphony," "Amplified" and "Conference."
This is the process we follow on concert hall projects:
1. Define the brief. Fix the use mix, audience capacity and target RT60 by frequency band.
2. Set the volume and shape. Check volume per seat and the room proportions.
3. Model it. Predict RT60 by band with tools such as CATT-Acoustic or Odeon.
4. Select materials. Use tested absorption data at each octave band.
5. Design the adjustable systems. Size banners or curtains for the range between your longest and shortest targets.
6. Build and coordinate. Align finishes, HVAC noise, lighting and rigging.
7. Measure and tune. Test to ISO 3382-1 and fine-tune.
Measurement closes the loop. Published targets are usually mid-frequency values (500–1000 Hz) in the unoccupied room, so the specification stays consistent. ISO 3382-1 is the reference method.
Practical checks:
- Measure at several source and receiver positions.
- Record results in octave bands, not a single number.
- Repeat with banners in each preset.
- Compare against the model and adjust.
- Chasing a single number while ignoring low-frequency balance.
- Relying only on absorption instead of shaping the room.
- Ignoring the empty-versus-full difference.
- Under-specifying adjustable systems so operators never use them.
- Treating acoustics separately from the sound, lighting and rigging design.
Acoustics, stage machinery, LED displays, sound, lighting and control all affect each other. A banner track can collide with a lighting bar. A loudspeaker array can change how much absorption you need. SJAVL handles design, construction, supply, installation, commissioning, testing and long-term support under one contract. That means one party is accountable for the acoustic result.
1. What is a good reverberation time for a concert hall?
For symphonic music, 1.8–2.2 seconds at mid-frequencies is the usual target.
2. How do you reduce reverberation time?
Add absorption such as curtains, banners or panels, or reduce the volume. Motorized banners offer quick control.
3. Can one hall suit both orchestra and amplified music?
Yes, with variable acoustics. Retract the absorbers for orchestra and deploy them for amplified events.
4. Why does an audience change the RT60?
People and upholstered seats absorb sound, so an occupied hall is shorter in decay than an empty one. Standards usually specify the condition.
5. What is Sabine's formula?
T = 0.161 V/A, linking reverberation time to volume and absorption.
6. How is RT60 measured?
By ISO 3382-1 methods, in octave bands, at multiple positions.

- [Concert Hall Acoustics | RT60, EDT, C80 & ISO 3382-1 – AcousPlan]
- [Concert Hall Acoustic Requirements – AcousPlan]
- [Sabine and reverberation – Brandeis University]
- [RT60 Chart: Reverberation Time Targets by Space Type – Commercial Acoustics]
- [Reverberation Time for Different Rooms – Commercial Acoustics]
- [Adjustable Acoustics – American Society of Theatre Consultants]
- [Variable Acoustics in Performance Venues: A Review – ScienceCentral]
- [Transform Motorized Acoustical Banners – Wenger]
What Are The Acoustic Requirements for A Live Streaming Studio? SJAVL’s Practical Design Guide
How To Design An Esports Stage for Live Gaming Events: An EPC Planning Guide
How To Design A Stage Lighting Control System for Live Performances: SJAVL’s Practical Guide
Why A Contractor Preferred A Turnkey Acoustic & AV Scope Over Multiple Subcontracts
Mixing Room Vs Mastering Room: Key Acoustic Differences | SJAVL’s Studio Design Guide
Acoustic Design Vs AV System Integration for Large Multipurpose Venues: An EPC Planning Guide
Fixed Acoustic Treatment Vs Variable Acoustics for Multi-Use Auditoriums: An EPC Design Guide